Double Louvre Damper Gate
Twin-row louvre gate with sealing air between the blade banks — 99.9 % sealing efficiency and pressure loss below 50 Pa when open.
Double louvre dampers, FGD isolation gates, round and square air dampers, slide gates and spring supports — designed, fabricated and tested in one works, then shipped worldwide.
From the boiler outlet to the stack, every isolation and regulating position is covered by a standard product — and anything outside the range is built to drawing.
Twin-row louvre gate with sealing air between the blade banks — 99.9 % sealing efficiency and pressure loss below 50 Pa when open.
Louvre-type gate for flue gas desulfurization systems, supplied as single-blade or zero-leak double-blade with sealing air.
Two parallel blade shafts linked by tie rods, driven by electric actuators — built for very large rectangular flue sections.
Linear-characteristic regulating damper for cold and hot air ducts, with ball-jointed linkage and no lost motion.
Circular double-shaft gate for large diameter flue ducts, with bolted flange mounting and linked blade banks.
A single plate that drops into the gas path to give a visible physical break, used for maintenance isolation on flue ducts where a louvre gate cannot guarantee a seal.
Technical design, production, quality inspection, sales and after-sales service sit under one integrated management system, so nothing is lost between the drawing and the delivered gate.
Our dampers serve the power, chemical, petroleum and metallurgy industries, and the company is certified to a quality management system — the basis for reliable products and after-sales support.
Working in the spirit of innovation and progress, we aim at long, friendly and mutually beneficial relationships — and answer service requests the same working day.
Fourteen product families across three groups. Pick the position you need to isolate or regulate.
Heavy-duty isolation gates for boiler flue ducts, with single or double blade rows.
Double louvre gas dampers with sealing air, designed for zero-leakage duty.
Regulating and shut-off dampers for cold and hot air ducts with linear characteristics.
Corrosion-resistant gates for wet FGD inlet, outlet and bypass service.
Circular isolation and throttling dampers for round air and flue ducts.
Rectangular multi-blade dampers for large air ducts and rectangular flue runs.
Guillotine-type gates that give a physical, visible break in the gas path.
Light-duty flap dampers for low-pressure air and dust-laden gas lines.
Abrasion-resistant gates for coal bunkers, feeders and pulverizer outlets.
Compact blade valves for tight shut-off on small and medium ducts.
Saddle-seat slide gates with hard and soft sealing for dust-laden ducts.
Zero-leakage valves for isolating gas and air branches during maintenance.
Rising-spindle gate valves for isolating dust and ash handling lines.
Variable and constant spring supports, rigid hangers and sliding supports for ductwork.
Power generation is our home market; the same construction logic carries into FGD, petrochemical, metallurgy, chemical and cement plants.
Damper gates, air dampers and duct components for coal, gas and biomass power plants.
Zero-leakage isolation for wet limestone-gypsum FGD absorbers and wet ESP trains.
Duct dampers, isolation gates and supports for refinery heaters, FCC and utility systems.
Abrasion-resistant dampers and gates for sinter, blast furnace and coke oven gas lines.
Corrosion-resistant duct valves and dampers for acid, alkali and fertilizer process lines.
Heavy-duty dampers for kiln, preheater and raw mill gas circuits.
A gate is only right when it matches the duty at its own position. These are the five application problems we are asked about most often, and how we solve them.
All solutionsA matched set of raw gas, clean gas and bypass gates that lets the absorber be opened while the unit stays on load.
Air preheater, ID fan and stack isolation using double-shaft gates sized to the duct section.
Linear-characteristic dampers with ball-jointed linkage for stable control loops.
Material and lining selection for the wet, chloride-bearing sections of the FGD duct.
Design and fabrication of non-standard dampers, gates, supports and flue components to drawing.
Design, fabrication and pressure testing under one roof in Yancheng, Jiangsu — drawings issued for approval before any steel is cut.
Yancheng Baoze Power & Petrochemical Machinery Co., Ltd. has years of production and design experience in the flue work of power stations, with a strong technical team and refined workmanship. Years of innovation have made us a manufacturer with a complete range, many specifications, reliable quality and good service.
We build to the Typical Design of Flue, Air and Pulverized Coal Piping Components for Fossil Fuel Power Plants prepared by the Northwest Electric Power Design Institute and the East China Design Institute, and our equipment is in service with customers throughout China.
ISO 9001 certification and utility model patents covering damper sealing structures and drive arrangements.
Sealing systems, material selection and maintenance practice — written by the people who build the gates.
None of these mistakes look like mistakes at the quotation stage. All of them cost real money once the unit…
Shaft horizontal or vertical, actuator above or below, housing on the pressure side or the suction side…
Speed, fail position, torque at speed and what the plant already knows how to maintain. The four questions…
The 0.5 % rule of thumb, when it is wrong, and the measurement that proves the seal on the day the permit is…
Send the duct section, the design temperature and pressure difference, and the duty point. A general arrangement drawing and a firm quotation come back within one working day.
No. 5 Hede Road, Sheyang Industrial Park, Yancheng, Jiangsu, China
Tell us the duct section, design temperature and pressure difference. We will come back with a general arrangement drawing and a price.
Drawings, material certificates and a firm quotation, usually within one working day.